Then the air is drawn into the open return side of the air handler located just a few feet away from the inlet and distributed via the air handler to the occupied rooms in the.
Make up air from attic.
Incoming air can be heated with electric resistance strips.
Attic as make up air i know you re in ca so the requirements are probably different.
It is important that the air being exhausted from the attic is properly replaced with outside air drawn up through ample soffit vents that have been properly installed with even spacing under the eaves.
There just isn t enough air leaks in the house to provide the make up air so in order for the exhaust fan to do its job we need to provide a duct for make up air.
In an exhaust based ventilation system the air that is drawn into a space is called make up air.
Connect an outside air duct to the plenum on the furnace if the house has a forced air heating and cooling system.
The air that enters cracks in a home s envelope to replace air that is exhausted is called makeup air.
The house is so tight 0 39ach 50 that when the range exhaust fan is operating without the make up duct open there is less than 30 cfm being exhausted.
The continuous stream of fresh air drawn in by this fan is dumped directly into the attic where it is tempered and preconditioned by mixing with air in the space.
Utility room is not closed off in any way to the rest of the house.
Belliott bob elliott 450 0002662 july 3 2010 12 40am 3.
Makeup combustion air for the water heater is via a floor vent to the crawl space and a ceiling vent to the unheated attic above.
The ceiling vent is a 6 inch rigid vertical circular air duct that opens to the attic and extends about 4 feet up from the utility room ceiling.
Ok to take make up air from an attic but this implementation is not proper nor is it ok to have an opening from the garage into the attic if the ceiling is providing fire separation.
In the case of make up air ducts the opening between the attic and the room is not considered a concealed draft opening.
Make up air is required to combat negative pressure in a home created by running a large ventilation unit.
When negative pressure occurs air will be pulled into the structure from somewhere.
Two existing building practices affecting makeup air are causing increasing problems for homeowners.
Hi everyone i ve visited this site a couple times but this is my first post.
Install a makeup air kit from fantech or electro industries.
But fire blocking for a single family house is defined in the irc section 602.
I have a goodman 93 high efficency natural gas furnace located in my single story home in the utility room.
Original installers used pvc to vent the furnace to the roof but combustion air for the furnace is pulled from inside the house.
If there are gas run appliances in the home then a deadly backdraft can occur but that is not the only issue.